This section applies to OSVs of at least 6,000 GT ITC (500 GRT if GT ITC is not assigned). Cargo tanks containing flammable or combustible liquids must not be located beneath the accommodations or machinery space. Each OSV must carry dry chemical extinguishers unless it complies with paragraph (d)(1). An OSV with fixed cargo tanks of 3,000 cubic meters or more aggregate capacity for liquids with a closed-cup flashpoint of 60 °C or below must have the foam system and the fixed-gas or other approved system described in paragraph (d).
Applies toOSVs of at least 6,000 GT ITC (500 GRT if GT ITC is not assigned).
What it says
Cargo tanks containing flammable or combustible liquids must not be located beneath the accommodations or machinery space, and separation by cofferdams does not meet this requirement.
46 CFR 132.390(b)“Cargo tanks containing flammable or combustible liquids must not be located beneath the accommodations or machinery space. Separation by cofferdams is not acceptable for meeting this requirement.”
Except for OSVs complying with paragraph (d)(1), each OSV must carry at least two approved semiportable dry chemical fire extinguishers protecting weather deck areas within 10 feet (3 m) of tank openings, pumps, flanges, valves, vents, or loading manifolds.
46 CFR 132.390(c)“each OSV must carry at least two approved semiportable dry chemical fire extinguishers for the protection of all weather deck areas within 10 feet (3 m) of any tank openings, pumps, flanges, valves, vents, or loading manifolds.”
Each required dry chemical extinguisher must have a minimum flow rate of 3 kg/min from each discharge hose.
46 CFR 132.390(c)(2)“A minimum flow rate of 3 kg/min from each discharge hose;”
Each OSV with fixed cargo tanks of 3,000 cubic meters or more aggregate capacity, intended for flammable or combustible liquids with a closed-cup flashpoint of 60 °C or below, must have the systems listed in paragraph (d).
46 CFR 132.390(d)“Each OSV with fixed cargo tanks that have an aggregate capacity of 3,000 cubic meters or more intended for the carriage of flammable or combustible liquids with a closed-cup flashpoint of 60 °C or below must have:”
For such an OSV, all foam liquid concentrate in the approved fixed-deck foam system must be compatible with all flammable or combustible liquids carried.
46 CFR 132.390(d)(1)(iii)“All foam liquid concentrate must be compatible with all flammable or combustible liquids carried.”
For such an OSV, the vessel must carry enough foam liquid concentrate to operate the foam system at its maximum discharge rate for at least 20 minutes.
46 CFR 132.390(d)(1)(iv)“Sufficient foam liquid concentrate must be carried to allow operation of the system at its maximum discharge rate for at least 20 minutes.”
For such an OSV, accessible below-deck cargo pump rooms or other spaces with tank openings, pumps, flanges, valves, or loading manifolds for these liquids must have a fixed-gas fire-suppression system complying with § 34.05-5(a)(4) of this chapter, or another approved system the Commandant finds acceptable.
46 CFR 132.390(d)(2)“A fixed-gas fire-suppression system complying with § 34.05-5(a)(4) of this chapter, or other approved fire-extinguishing system determined acceptable by the Commandant”
Common questions
Which OSVs does 46 CFR 132.390 apply to?
It applies to OSVs of at least 6,000 GT ITC, or 500 GRT if GT ITC is not assigned.
“This section applies to OSVs of at least 6,000 GT ITC (500 GRT if GT ITC is not assigned).”
Can flammable liquid cargo tanks be under the accommodations on an OSV?
No. Cargo tanks containing flammable or combustible liquids must not be located beneath the accommodations or machinery space, and cofferdams do not satisfy this.
“Cargo tanks containing flammable or combustible liquids must not be located beneath the accommodations or machinery space.”
How long must an OSV's foam concentrate supply last?
For an OSV with the foam system required by paragraph (d)(1), the vessel must carry enough foam liquid concentrate to operate the system at its maximum discharge rate for at least 20 minutes.
“Sufficient foam liquid concentrate must be carried to allow operation of the system at its maximum discharge rate for at least 20 minutes.”
The text of 46 CFR 132.390
Electronic Code of Federal Regulations (eCFR), current as of April 16, 2026 · Read it on eCFR
Added requirements for carriage of flammable or combustible cargo
(a) This section applies to OSVs of at least 6,000 GT ITC (500 GRT if GT ITC is not assigned).
(b) Cargo tanks containing flammable or combustible liquids must not be located beneath the accommodations or machinery space. Separation by cofferdams is not acceptable for meeting this requirement.
(c) Except for OSVs complying with paragraph (d)(1) of this section, each OSV must carry at least two approved semiportable dry chemical fire extinguishers for the protection of all weather deck areas within 10 feet (3 m) of any tank openings, pumps, flanges, valves, vents, or loading manifolds. Each extinguisher must have—
(1) A minimum capacity of 135 kg. If the protected area exceeds 90 m 2, additional extinguishers must be provided to supply a total combined capacity of dry chemical in kilograms equal to the total combined protected area in square meters multiplied by 3;
(2) A minimum flow rate of 3 kg/min from each discharge hose;
(3) A sufficient number of discharge hoses of adequate length to protect the areas required above without moving any of the extinguishers; and
(4) The frame or support for each semi-portable dry chemical fire extinguisher welded or otherwise permanently attached to the vessel's structure.
(d) Each OSV with fixed cargo tanks that have an aggregate capacity of 3,000 cubic meters or more intended for the carriage of flammable or combustible liquids with a closed-cup flashpoint of 60 °C or below must have:
(1) An approved fixed-deck foam system arranged as follows:
(i) If the flammable or combustible liquid tanks extend vertically to the weather deck, the foam system must comply with §§ 34.20-10 and 34.20-15 of this chapter, and protect the entire weather deck cargo area, including any tank openings, pumps, flanges, valves, vents, or loading manifolds. If petroleum products are carried, the minimum foam system discharge rate in liters per minute must be determined by multiplying the total cargo deck area by 6 lpm/m 2. If polar solvent cargoes are carried, the minimum foam system discharge rate in liters per minute must be determined by multiplying the total cargo deck area by 10 lpm/m 2, unless the approved foam system design manual specifies a different rate for the cargoes carried.
(ii) If the flammable or combustible liquid tanks do not extend vertically to the weather deck, the foam system must be capable of protecting all weather deck areas within 10 feet (3 m) of any tank openings, pumps, flanges, valves, vents, or loading manifolds. The foam system must consist of at least one hoseline, and either fixed-foam monitors or fixed-foam nozzles that provide foam coverage of all required areas. The minimum foam system discharge rate must be calculated in accordance with paragraph (d)(1)(i) of this section, using the combined horizontal area of all parts of the deck requiring protection, instead of the total deck area.
(iii) All foam liquid concentrate must be compatible with all flammable or combustible liquids carried.
(iv) Sufficient foam liquid concentrate must be carried to allow operation of the system at its maximum discharge rate for at least 20 minutes.
(2) A fixed-gas fire-suppression system complying with § 34.05-5(a)(4) of this chapter, or other approved fire-extinguishing system determined acceptable by the Commandant, for the protection of any accessible below-deck cargo pump rooms or other spaces that have tank openings, pumps, flanges, valves, or loading manifolds associated with tanks carrying flammable or combustible liquids with a closed cup flashpoint of 60 °C or below.
Sections it refers to
The plain-English explanation on this page was written with AI from the regulation text above and checked automatically before publishing: every quote appears in the text, every number comes from it, and a second model confirmed each statement adds nothing the text doesn't say. Regulation text current as of April 16, 2026. The regulation text governs. RegKnot is not affiliated with the U.S. Coast Guard.