46 CFR 34.05-5: Fire extinguishing systems on tankships

Last reviewed: October 14, 2026

This section requires approved fire extinguishing systems on tankships in the listed locations. The type of system depends on the space, and some requirements apply only to tankships or vessels with certain contract dates, sizes or voyages. Arrangements and details are set out in subparts 34.10 through 34.20.

Applies toTankships, with some paragraphs limited by contract date, size or voyage as the text states.

What it says

  1. Approved fire extinguishing systems must be installed on all tankships in the locations listed in paragraph (a), and previously approved installations may be retained if maintained in good condition to the satisfaction of the Officer in Charge, Marine Inspection.

    46 CFR 34.05-5(a)“Previously approved installations may be retained as long as they are maintained in good condition to the satisfaction of the Officer in Charge, Marine Inspection.”
  2. A carbon dioxide or water spray system must be installed to protect all dry cargo compartments.

    46 CFR 34.05-5(a)(1)“A carbon dioxide or water spray system must be installed for the protection of all dry cargo compartments.”
  3. Where dry cargo compartments are readily accessible by means of doors, those spaces need be protected only by the fire main system.

    46 CFR 34.05-5(a)(1)“Where such compartments are readily accessible by means of doors such spaces need be protected only by the fire main system.”
  4. A deck foam system must be installed to protect all cargo tank spaces.

    46 CFR 34.05-5(a)(2)“A deck foam system must be installed for the protection of all cargo tank spaces.”
  5. A carbon dioxide or clean agent system as described in 46 CFR subpart 95.16, or a water spray system, must be installed in all lamp and paint lockers, oil rooms, and similar spaces.

    46 CFR 34.05-5(a)(3)“A carbon dioxide or clean agent system as described in 46 CFR subpart 95.16 or a water spray system must be installed in all lamp and paint lockers, oil rooms, and similar spaces.”
  6. A carbon dioxide or clean agent system as described in 46 CFR subpart 95.16, a foam spray system, or a water spray system must be installed to protect all pump rooms.

    46 CFR 34.05-5(a)(4)“A carbon dioxide or clean agent system as described in 46 CFR subpart 95.16, a foam spray system, or a water spray system must be installed for the protection of all pump rooms.”
  7. A carbon dioxide or clean agent system as described in 46 CFR subpart 95.16 must be installed to protect any machinery space containing an internal combustion-propelling engine that uses fuel having a flashpoint of less than 110 degrees Fahrenheit.

    46 CFR 34.05-5(a)(6)“must be installed to protect any machinery space containing an internal combustion-propelling engine that uses fuel having a flashpoint of less than 110 degrees Fahrenheit.”
  8. The arrangements and details of the fire-extinguishing systems shall be as set forth in subparts 34.10 through 34.20.

    46 CFR 34.05-5(b)“The arrangements and details of the fire-extinguishing systems shall be as set forth in subparts 34.10 through 34.20.”

Common questions

What fire extinguishing system is required for tankship cargo tanks?

A deck foam system must be installed to protect all cargo tank spaces. Where a deck foam system is installed, an approved inert gas, steam or other system may also be installed for fire prevention or inerting.

“A deck foam system must be installed for the protection of all cargo tank spaces.”

What systems are allowed for tankship pump rooms?

A carbon dioxide or clean agent system as described in 46 CFR subpart 95.16, a foam spray system, or a water spray system must be installed to protect all pump rooms.

“A carbon dioxide or clean agent system as described in 46 CFR subpart 95.16, a foam spray system, or a water spray system must be installed for the protection of all pump rooms.”

Can older approved fire extinguishing installations on a tankship stay in place?

Yes. Previously approved installations may be retained if they are maintained in good condition to the satisfaction of the Officer in Charge, Marine Inspection.

“Previously approved installations may be retained as long as they are maintained in good condition to the satisfaction of the Officer in Charge, Marine Inspection.”

Do easily accessible dry cargo compartments need a carbon dioxide or water spray system?

No. Where they are readily accessible by means of doors, they need be protected only by the fire main system.

“Where such compartments are readily accessible by means of doors such spaces need be protected only by the fire main system.”

The text of 46 CFR 34.05-5

Electronic Code of Federal Regulations (eCFR), current as of March 31, 2026 · Read it on eCFR

Fire extinguishing systems—T/ALL

(a) Approved fire extinguishing systems must be installed on all tankships in the following locations. Previously approved installations may be retained as long as they are maintained in good condition to the satisfaction of the Officer in Charge, Marine Inspection.

(1) Dry cargo compartments. A carbon dioxide or water spray system must be installed for the protection of all dry cargo compartments. Where such compartments are readily accessible by means of doors such spaces need be protected only by the fire main system.

(2) Cargo tanks. A deck foam system must be installed for the protection of all cargo tank spaces. Where a deck foam system is installed, an approved inert gas, steam or other system may also be installed for the purposes of fire prevention or inerting of cargo tanks. For vessels under 100 feet in length, the semiportable equipment required by footnote 1 of table 34.05-5(a) will be considered as meeting the requirements of this subparagraph.

(3) Lamp and paint lockers and similar spaces. A carbon dioxide or clean agent system as described in 46 CFR subpart 95.16 or a water spray system must be installed in all lamp and paint lockers, oil rooms, and similar spaces.

(4) Pump rooms. A carbon dioxide or clean agent system as described in 46 CFR subpart 95.16, a foam spray system, or a water spray system must be installed for the protection of all pump rooms. If a clean agent system is installed for the pump room of a tank ship carrying chemical cargos, the amount of extinguishing agent must be determined by using the agent design concentration determined by the cup burner method, described in NFPA 2001 (incorporated by reference; see § 34.01-15) for the cargo requiring the greatest amount of agent.

(5) Boiler rooms. On tankships contracted for on or after November 19, 1952, a carbon dioxide or clean agent system as described in 46 CFR subpart 95.16 or a foam system must be installed to protect any space containing a main or auxiliary oil fired boiler, the boiler fuel oil service pump, or any fuel oil units such as heaters, strainers, valves, manifolds, etc., that are subject to the discharge pressure of the fuel oil service pumps.

(6) Machinery spaces. A carbon dioxide or clean agent system as described in 46 CFR subpart 95.16 must be installed to protect any machinery space containing an internal combustion-propelling engine that uses fuel having a flashpoint of less than 110 degrees Fahrenheit.

(7) Internal combustion installations. A fire extinguishing system must be provided for an internal combustion installation and:

(i) The system must be a carbon dioxide or clean agent system as described in 46 CFR subpart 95.16;

(ii) On vessels of 1,000 gross tons and over on an international voyage, the construction or conversion of which is contracted for on or after May 26, 1965, a carbon dioxide or clean agent system as described in 46 CFR subpart 95.16 must be installed in any space containing internal combustion or gas turbine main propulsion machinery, auxiliaries with an aggregate power of 1,000 b.h.p. or greater, or their fuel oil units, including purifiers, valves, and manifolds; and

(iii) On vessels of 1,000 gross tons and over, the construction, conversion or automation of which is contracted for on or after January 1, 1968, a carbon dioxide or clean agent system as described in 46 CFR subpart 95.16 must be installed in any space containing internal combustion or gas turbine main propulsion machinery, auxiliaries with an aggregate power of 1,000 b.h.p. or greater, or their fuel oil units, including purifiers, valves and manifolds.

(8) Enclosed ventilating system. On tankships contracted for on or after January 1, 1962, where an enclosed ventilating system is installed for electric propulsion motors or generators, a carbon dioxide extinguishing system shall be installed in such system.

(b) The arrangements and details of the fire-extinguishing systems shall be as set forth in subparts 34.10 through 34.20.

Sections it refers to

The plain-English explanation on this page was written with AI from the regulation text above and checked automatically before publishing: every quote appears in the text, every number comes from it, and a second model confirmed each statement adds nothing the text doesn't say. Regulation text current as of March 31, 2026. The regulation text governs. RegKnot is not affiliated with the U.S. Coast Guard.